Check out put signal of 'MOLD CLOSE' (in HAND operation)
Defect of loose connection of solenoid valve coil.
Check solenoid valve coil connection if loose, tightened it. Check continuity of solenoid valve coil if burnout replace it. Disconnect solenoid valve coil. Join the Connection.
Check the circuit according to the electrical circuit diagram.
Safety gate open (in semi/fully automatic operation)
Close the safety gate properly.
Defective cycle timer (in semi/fully automatic operation) Replace cycle timer.
Low hydraulic pressure. Increase to required level.
Check out put signal of 'INJECTION' (in HAND operation)
Check circuit according to circuit diagram.
Defect or loose connection of solenoid valve coil. Defective coil
of solenoid valve.
Join the connection properly. If Coil is defective than replace.
Low temperature (In all operation) Check heater connection and
condition. Increase temperature as per requirement. Replace the
better heater band if necessary.
Defective torpido. Replace if necessary.
Injection pressure is too low (in all operation) Check injection pressure. Increase injection pressure as per requirement.
For PLC based control refer operator instructional manual.
Reading of temperature value too high or too low than heated portion. Check loose connection of thermocouple. Join connection properly Thermocouple seats not proper. Fix thermocouple with proper spring tension. Thermocouple connection (negative and positive) are open or short. Join the connection of negative and positive properly. Defective thermocouple, replace with new thermocouple, if necessary.
Check the OUT PUT SIGNAL of heating.
Check the loose contact or connection of heating contactor. Replace the contact or contactor if necessary.